products

Reduce Power Consumption Ata Center 102kW LionRock ODM OEM

Basic Information
Place of Origin: Dongguan China
Brand Name: LionRock
Minimum Order Quantity: negotiate
Price: negotiate
Packaging Details: export packing
Delivery Time: negotiate
Payment Terms: TT
Detail Information
Total ICT Design Load: 56~93kW Design Load Per STD Cabinet: 5.6~9kW
Design Load Per Deep Cabinet: 8~13kW DC System Capacity: Up To 102kW
Cooling Type: Direct Expansion, In-row System Type: Automatic Fire Detection With Gas Suppression System
High Light:

OEM Ata Center

,

102kW Ata Center

,

Ata Prefabricated Data Center


Product Description

Reduce Power Consumption Ata Center 102kW LionRock ODM OEM
 
Introduction
 
With the demand of data communication and edge computing, telecommunication need to deploy medium scale data centre with data communication capability much quicker and more to meet the 5G network development.
 
DataCage is the product developed to address this need in the market. Other than typical mobile data centre, DataCage offers mixed IT (information technology) and CT (communication technology) power and energy infrastructure in a prefabricated ISO container allowing immediate installation of server and telecom equipment to shorten the deployment and commissioning time. DataCage is designed to operate in various terrains as well as harshest environments. The DataCage integrated power supply and distribution (UPS, rectifiers and batteries), CRAC (computer room air conditioning), IT and CT equipment racks.
 
Reduce Power Consumption Ata Center 102kW LionRock ODM OEM 0
 
- High energy efficiency: designed to reduce power consumption and operating costs. State of the art cooling system with cold/hot aisle containment and in-row CRAC units.
Reliability: redundant and fault tolerant capabilities according to Uptime Institute guidelines for Tier II and Tier III facilities.
- Modularity: the standard ISO container enclosure ensure easy transportation all over the world. Easily scalable with additional modules.
- ICT cabinet flexibility: supports various ICT cabinet dimensions. Different combinations of IT and CT cabinets according to specific design needs.
- ICT load flexibility: CRACs along with UPS and rectifiers can be configured to support different ICT loads.
Optimized space use: up to 12 ICT cabinets in an ISO40HC container.
Alternative power supplies: Mains power and standby power connection available.
- Security: CCTV surveillance system and control access.
Fire protection: automatic fire detection and suppression system with clean agent.
- Central management: complete monitoring of the status of the different subsystems. Remote access by multiple
users.
Optional features and customized layouts possible.
 
Power Supply and Distribution
- Dual power inputs with automatic changeover for grid and standby generator system.
- Redundant configuration of power distribution paths as required.
- Support of IT and telecom equipment with different power and energy requirements.
- Configurable distribution of IT and CT cabinets.
- Modular UPS and DC rectifier system with redundant hot- swappable modules.
- High efficient UPS (>96%) with maintenance bypass.
- UPS with standard 15 minutes of battery backup time with option for longer duration.
- Intelligent battery management system.
 
Precision Cooling
- Cooling design according to CFD (computational fluid dynamics) simulation to optimize airflow distribution.
- Redundant configuration of in-row precision CRAC units.
- Variable speed compressor to adapt to server temperature.
- Variable speed and redundant fans.
- Easy-maintenance design with front and rear access panels.
- Replacement of CRAC units by sliding adjacent equipment cabinets.
- Outdoor condenser location to maximize indoor space.
 
Application Scenarios
- Increase of processing and storage capacity in existing premises with space limitations.
- Data center deployment in distributed and remote locations for commercial and industrial use.
- Immediate transportation and installation of data center for temporary situations such as disaster recovery, military operations, or cultural/sporting events.
- Deployment of telecom equipment room for radio access and optical networks.
- Edge computing.
 
Layout
Reduce Power Consumption Ata Center 102kW LionRock ODM OEM 1
 
The internal surface of the container is insulated to minimise the energy loss.
 
The cold and hot aisle containment are separated to control the return temperature to CRAC which improve the efficiency and reduce the PUE.